Filter Results By:

Products

Applications

Manufacturers

Impedance Analyzers

characterize impedance.

See Also: Frequency Response Analyzers, Frequency Analyzers, Network Analyzers, Impedance Testers


Showing results: 151 - 156 of 156 items found.

  • Battery Analyzers

    BA6010 Series - B&K Precision Corporation

    The BA6010 Series battery analyzers measure voltage and resistance of modern battery technologies with high accuracy, resolution, and speed. Additionally, these instruments provide auxiliary measurement parameters inductance, capacitance, dissipation factor, impedance, quality factor, reactance, and phase angle in degrees and radians. The BA6010 Series is suitable for characterizing battery chemistries that are responsive to a 1 kHz AC stimulus signal including lead acid, lithium and alkaline type batteries used in consumer products, electric vehicles, power backup, security, and fire alarm systems.

  • Vector Network Analyzer

    R42XXE - Elmika

    The R42XXE Vector Network Analyzers are designed for measuring of S-parameters, VSWR and impedance of waveguide networks in the full frequency ranges of standard waveguides between 33 and 170 GHz. Frequency accuracy is ±0.2%. The measurement range of reflection factor modulus is from 0 to 1. The measurement range of reflection factor phase is from 0 to ±180° for 0.1< |Гx|<1 with accuracy ±7.5 o in 18-75 GHz frequency range and ±9.6° in 75-170 GHz frequency range. The measurement range of transmission factor phase is from 0 to ±180 o with accuracy ±(5+0.1 |Ax|) o for Ax >-50 dB in frequency range to 75 GHz, for Ax >-30 dB - to 170 GHz. Data can be displayed in the rectangular, Smith or polar diagrams. VNA requires Personal Computer with USB interface.

  • Micro probes 1 MHz up to 6 GHz

    MFA 01 set - Langer EMV-Technik GmbH

    The micro probes are used to measure magnetic fields and they have a high resolution. They measure magnetic fields up to 6 GHz, e.g. at signal conductors (150µm), SMD components (0603-0201) or IC pins. The MFA micro probes are guided by hand. An amplifier stage is integrated into the probe head. The amplifier stage (9V, 100mA) is powered via the Bias tee BT 706. It has an impedance of 50 Ohm. The micro probes are connected via the Bias tee BT 706 to a spectrum analyzer or an oscilloscope. Langer EMV-Technik GmbH includes correction lines in the delivery. With the help of the correction lines the probe output voltage is converted either into the respective magnetic field or to the current which is running through the conductor.

  • Micro probes 1 MHz up to 1 GHz

    MFA 02 set - Langer EMV-Technik GmbH

    The two in the set included micro probes are used to measure low-frequency magnetic fields up to 1 GHz, e.g. at signal conductors (150µm), SMD componets (0603-0201) or IC pins. The MFA micro probes are guided by hand. An amplifier stage is integrated into the probe head. The amplifier stage (9V, 100mA) is powered via the BT 706 Bias tee. It has an impedance of 50 Ohm. The micro probes are connected via the Bias tee to a spectrum analyzer or an oscilloscope. The MFA 02 set delivery of Langer EMV-Technik GmbH includes correction lines. With the help of the correction lines the probe output voltage is converted either into the respective magnetic field or to the current which is running through the conductor.

  • Amplitude Detectors with Isolators

    ERAVANT

    Full band waveguide detectors are GaAs beam lead Schottky diode-based detectors that are specially designed for millimeterwave network analyzer applications. With a proprietary circuitry design and careful diode selection, these zero-biased detectors exhibit high sensitivity and extremely flat output characteristics. The below standard offering covers the frequency range of 18 to 170 GHz and offers a 1 MHz video bandwidth and 1 MΩ video output impedance. The standard models also have the capacity to handle a maximum RF input power of up to +17 dBm. The RF interface of these detectors is a standard waveguide with an integrated Faraday isolator to improve the port VSWR. The output voltage polarity is negative and the connector type is a female SMA. Other configurations are offered as custom models.

  • Harmonic/Flicker Analyzer for IEC61000-3-2/3/11/12, IEC61000-4/7/15

    KHA3000 - Kikusui Electronics Corp.

    KHA3000, in addition to the complied standards and features of the KHA1000 (dedicated for single phase), is equipped for the harmonic and flicker compliance test exceeding 16A of the single-phase and three-phase equipment. With this unit alone, you can take highly accurate simultaneous three-phase measurements up to 40A/phase*. Furthermore, the KHA series is compliant with two measurement technique standards, the existing and the latest versions, so you can simply select to take measurements for the latest standard including interharmonics and for the conventional integral multiple harmonics without using any other device. In addition to the real-time display that can be used like an oscilloscope and FFT analyzer, the unit offers the real-time judgment of compliance with standards. Using this unit alone, you can judge test results and prepare result reports without the use of a PC. On top of that, you can easily set up a test system by combining KHA3000 with an AC power supply (PCR-LA Series) and a line impedance network (LIN40MA-PCR-L).

Get Help